In the world of off-grid solar and mobile power systems, 그만큼 “48100AH에서 LiFePO4 battery paired with a 2000W inverter” is one of the most popular configurations. It strikes a balance between portability, voltage efficiency, and power output. 하지만, many users often overestimate their runtime by simply dividing the total energy by the load. To calculate the 실제 runtime, we must account for efficiency losses, 방전 깊이 (국방부), and inverter overhead.
The Theoretical vs. Practical Calculation
To find the runtime, we first determine the total energy stored in the battery.
-
총에너지 (와트시) = 전압 (V) × Capacity (아)
-
48V × 100Ah = 4,800 와트-시간 (와트시)
그만큼 “Real-World” Multipliers
You cannot use 100% of the 4,800Wh. You must apply two critical factors:
-
Inverter Efficiency ($\eta$): Inverters are not 100% 효율적인; they lose energy as heat during conversion. A high-quality pure sine wave inverter typically operates at 85%–90% efficiency.
-
배출 깊이 (국방부): While LiFePO4 batteries can be discharged deeply, consistently drawing them down to 0% reduces their cycle life. For a healthy system, we assume an 80%–90% usable capacity.
Formula for Estimated Runtime:

Runtime Estimation Table (at 2000W Load)
The following table demonstrates how your runtime changes based on real-world factors.
| Scenario | 사용 가능한 용량 (와트시) | Inverter Efficiency | Effective Power Available | Estimated Runtime (Hrs) |
| Theoretical (100%) | 4,800 | 100% | 2,000w | 2.40 |
| Conservative (80%) | 3,840 | 85% | 1,700w | 1.63 |
| Optimized (90%) | 4,320 | 90% | 1,800w | 1.94 |
Key Factors Influencing Your Results
1. The Peukert Effect & Voltage Sag
납산 배터리와 달리, LiFePO4 batteries maintain a very stable voltage curve. 하지만, at a high draw of 2000W, you are pulling approximately 42 앰프 from a 48V bank. This sustained current will cause a slight voltage drop, which may cause your inverter to reach its “Low Battery” cutoff alarm earlier than expected if the battery cables are undersized.
2. 인버터 “Idle Consumption”
Even when the load is not pulling the full 2000W, your inverter consumes power just by being “on.” This is known as “tare loss” 또는 “idle power.” A 2000W inverter can consume 20W to 50W per hour just to stay powered, which effectively lowers your total efficiency over a 24-hour period.
3. Temperature Sensitivity
As discussed in our previous technical deep-dive, LiFePO4 capacity drops in cold weather. If you are operating this 48V system in temperatures near freezing, expect your runtime to drop by an additional 10%–15% due to increased internal resistance.
Engineering Recommendations for Maximum Runtime
-
케이블 크기: At 48V, a 2000W draw requires cables sized at least 4 AWG (또는 2 AWG for longer runs). Inadequate cabling causes heat and voltage drops, triggering the inverter’s low-voltage protection prematurely.
-
Inverter Selection: Always choose a “Low Frequency” pure sine wave inverter for high-load applications. They are heavier and more expensive but offer higher surge capacities and better thermal management compared to “High Frequency” 모델.
-
Monitor Your State of Charge (사회): Use a shunt-based battery monitor (like a Victron SmartShunt). Relying on the battery’s voltage to determine capacity is inaccurate with LiFePO4 because the voltage remains flat for most of the discharge cycle.
결론
While a 48V 100Ah battery stores 4.8kWh, do not expect to run a 2000W appliance for 2.4 시간. In a real-world, healthy setup, you should plan for approximately 1.5 에게 1.8 hours of runtime to protect the longevity of your lithium cells and ensure system stability. Always build in a 20% margin to avoid unexpected shutdowns.
Please contact 우리를 for more information.